1Operating InstructionsRescue Tools84150/7060-85 GBIssue 02.2006replaces 07.2005Accu-toolLKE 50 / LKE 51LKE 55 / LKE 70external accu 7 Ah
108.4 Opening of tool armsThe LKE 55 motor starts automatically when the star grip (1) is turned to either "opening" or"closing".
119.2 SpreadingUse the frontmost area of the tips only for enlarging the gap. The maximum spreading force canbe applied if approx. 50% of the grooved
1210.5 Calibration of charger indication panelIf the external accumulator 7 Ah is frequently partially discharged, but then fully charged again, thepr
13If the capacity of the installed accu constantly decreases despite proper charging, it must bereplaced by a qualified person.Maintenance adviceApply
1415 Technical data*Weight (including oil filling, handle and carrier belt):Oil specifications: delivered with mineral oil HLP 10 DIN 51524 (closed oi
1515.2 Central bolt / Tightening torque15.3 Noise emission15.4 OthersType LKE 50 / LKE 51 LKE 70 LKE 55Central bolt M 24 x 1.5 (SW 36)Torque Nm 100+10
2Contents page1 Basic operation and designated use of the machine 42 Organizational measures 43 General safety instructions 44 Instructions for mainte
36 7 81 4 5326 7 82 1 4351 Star grip2 Main switch3 LED indication panel4 Handle5 Socket 24 V6 Blade arms7 Central bolt withself-locki
41 Basic operation and designated use of the machine1.1 The machine has been built in accordance with state-of-the-art standards and the recognizedsaf
53.2 Make sure that nobody is at risk before starting up or setting the machine in motion and duringoperation of the machine.3.3 Before transporting t
6Device-specific Information:Do not reach in between the blade arms!Do not cut electric wires!Cutting objects under tension (shock absorbers, springs,
76.4 Close device (cutting)Turn rotary knob upwards and start the tool.The direction/operation process of the tool can be changed even when the tool i
87.5 Load holding function / dead man’s functionAs soon as the star grip is released it automatically returns to the neutral "zero" position
9When the charger is switched off or disconnected from its electric supply, the LKE 70 (or theexternal accumulator) must be disconnected from the char
Kommentare zu diesen Handbüchern